Indore Power Upgrade: 132 kV Lines To Get Nearly 3X Capacity With HTLS Technology

Indore (Madhya Pradesh): In a major move to strengthen Indore's power infrastructure amid rising electricity demand, Madhya Pradesh Power Transmission Company (MP Transco) has begun uprating key 132 k...

Indore Power Upgrade: 132 kV Lines To Get Nearly 3X Capacity With HTLS Technology
Source: Free Press Journal - General

Indore (Madhya Pradesh): In a major move to strengthen Indore's power infrastructure amid rising electricity demand, Madhya Pradesh Power Transmission Company (MP Transco) has begun uprating key 132 kV transmission lines by replacing conventional ACSR Panther conductors with advanced High Temperature Low Sag (HTLS) conductors.The upgrade is expected to provide nearly three times the current-carrying capacity through existing transmission corridors, increasing power transfer without requiring new transmission lines. The move assumes significance as rapid urban expansion and construction activity in Indore are making land and Right of Way (ROW) for new transmission corridors increasingly difficult to secure.Work has begun on both circuits of the 132 kV transmission lines connecting the 220 kV Indore South Zone Substation at Khandwa Road with the 132 kV Chambal Substation through the Electronic Complex and Satya Sai circuits.Work has also commenced on both circuits connecting the 220 kV Indore North Zone Substation at Sanwer Road with the 132 kV Chambal Substation at Pologround.14 Feeder Bays Also Being UpgradedAlong with the transmission lines, MP Transco has initiated uprating of 14 feeder bays at the 132 kV Chambal Substation, 220 kV Indore South Zone Substation, 220 kV Indore North Zone Substat

ion, 132 kV Electronic Complex Substation and 132 kV Satya Sai Substation.Associated switchyard and feeder-bay equipment will also be upgraded to handle the higher current-carrying capacity of the HTLS conductors, enabling increased transmission capacity across the interconnected network.More Power Through Existing CorridorsHTLS conductors can operate at higher temperatures than conventional ACSR conductors while maintaining lower sag, allowing substantially more current and, consequently, more electrical power to be transmitted through existing lines.The technology is particularly useful in urban areas where acquiring ROW for new transmission corridors is challenging. By upgrading existing infrastructure, MP Transco can increase transmission capacity without constructing new corridors.The initiative is expected to improve load management on critical sections of Indore's 132 kV network and provide additional operational margin to handle rising power flows.The enhanced capacity will support the growing electricity requirements of Indore and adjoining areas while enabling better utilisation of existing infrastructure and reducing the immediate need for new ROW-intensive transmission lines.Indore Mayor Pushyamitra Bhargav & Other Leaders Take To Streets With Brooms As Sanitation Workers Take A Break

SOURCE: Free Press Journal - General
ORIGINAL REPORT: Click here
DHALLO EDITORIAL STATUS: Aggregated & reviewed
Have feedback on this article?Report error or suggestion

Read More from India

U.K. recognises India's carbon credit scheme under its carbon tax mechanism: official

With this recognition, U.K. importers of eligible Indian goods covered under CBA...

Read Article »

West Asia conflict updates: Iran warns U.S. energy assets in Gulf are vulnerable after latest clashes

Iranian Parliament Speaker Mohammad Bagher Ghalibaf warned the U.S. that the “ru...

Read Article »

Blockx first Belgian man to reach U.S. Open quarter-finals

The win marks the latest stepping stone for Blockx, who began the year outside t...

Read Article »
Return to Front Page

5 minutes. The news that matters.

Get the most important stories of the day, without having to browse hundreds of articles.